struct_regulator_ops (9) - Linux Manuals
struct_regulator_ops: regulator operations.
NAME
struct_regulator_ops - regulator operations.
SYNOPSIS
struct regulator_ops { int (* list_voltage) (struct regulator_dev *, unsigned selector); int (* set_voltage) (struct regulator_dev *, int min_uV, int max_uV,unsigned *selector); int (* map_voltage) (struct regulator_dev *, int min_uV, int max_uV); int (* set_voltage_sel) (struct regulator_dev *, unsigned selector); int (* get_voltage) (struct regulator_dev *); int (* get_voltage_sel) (struct regulator_dev *); int (* set_current_limit) (struct regulator_dev *,int min_uA, int max_uA); int (* get_current_limit) (struct regulator_dev *); int (* set_input_current_limit) (struct regulator_dev *, int lim_uA); int (* set_over_current_protection) (struct regulator_dev *); int (* set_active_discharge) (struct regulator_dev *, bool enable); int (* enable) (struct regulator_dev *); int (* disable) (struct regulator_dev *); int (* is_enabled) (struct regulator_dev *); int (* set_mode) (struct regulator_dev *, unsigned int mode); unsigned int (* get_mode) (struct regulator_dev *); int (* enable_time) (struct regulator_dev *); int (* set_ramp_delay) (struct regulator_dev *, int ramp_delay); int (* set_voltage_time) (struct regulator_dev *, int old_uV,int new_uV); int (* set_voltage_time_sel) (struct regulator_dev *,unsigned int old_selector,unsigned int new_selector); int (* set_soft_start) (struct regulator_dev *); int (* get_status) (struct regulator_dev *); unsigned int (* get_optimum_mode) (struct regulator_dev *, int input_uV,int output_uV, int load_uA); int (* set_load) (struct regulator_dev *, int load_uA); int (* set_bypass) (struct regulator_dev *dev, bool enable); int (* get_bypass) (struct regulator_dev *dev, bool *enable); int (* set_suspend_voltage) (struct regulator_dev *, int uV); int (* set_suspend_enable) (struct regulator_dev *); int (* set_suspend_disable) (struct regulator_dev *); int (* set_suspend_mode) (struct regulator_dev *, unsigned int mode); int (* set_pull_down) (struct regulator_dev *); };
MEMBERS
list_voltage
- Return one of the supported voltages, in microvolts; zero if the selector indicates a voltage that is unusable on this system; or negative errno. Selectors range from zero to one less than regulator_desc.n_voltages. Voltages may be reported in any order.
set_voltage
- Set the voltage for the regulator within the range specified. The driver should select the voltage closest to min_uV.
map_voltage
- Convert a voltage into a selector
set_voltage_sel
- Set the voltage for the regulator using the specified selector.
get_voltage
- Return the currently configured voltage for the regulator.
get_voltage_sel
- Return the currently configured voltage selector for the regulator.
set_current_limit
- Configure a limit for a current-limited regulator. The driver should select the current closest to max_uA.
get_current_limit
- Get the configured limit for a current-limited regulator.
set_input_current_limit
- Configure an input limit.
set_over_current_protection
- Support capability of automatically shutting down when detecting an over current event.
set_active_discharge
- Set active discharge enable/disable of regulators.
enable
- Configure the regulator as enabled.
disable
- Configure the regulator as disabled.
is_enabled
- Return 1 if the regulator is enabled, 0 if not. May also return negative errno.
set_mode
- Set the configured operating mode for the regulator.
get_mode
- Get the configured operating mode for the regulator.
enable_time
- Time taken for the regulator voltage output voltage to stabilise after being enabled, in microseconds.
set_ramp_delay
- Set the ramp delay for the regulator. The driver should select ramp delay equal to or less than(closest) ramp_delay.
set_voltage_time
- Time taken for the regulator voltage output voltage to stabilise after being set to a new value, in microseconds. The function receives the from and to voltage as input, it should return the worst case.
set_voltage_time_sel
- Time taken for the regulator voltage output voltage to stabilise after being set to a new value, in microseconds. The function receives the from and to voltage selector as input, it should return the worst case.
set_soft_start
- Enable soft start for the regulator.
get_status
- Return actual (not as-configured) status of regulator, as a REGULATOR_STATUS value (or negative errno)
get_optimum_mode
- Get the most efficient operating mode for the regulator when running with the specified parameters.
set_load
- Set the load for the regulator.
set_bypass
- Set the regulator in bypass mode.
get_bypass
- Get the regulator bypass mode state.
set_suspend_voltage
- Set the voltage for the regulator when the system is suspended.
set_suspend_enable
- Mark the regulator as enabled when the system is suspended.
set_suspend_disable
- Mark the regulator as disabled when the system is suspended.
set_suspend_mode
- Set the operating mode for the regulator when the system is suspended.
set_pull_down
- Configure the regulator to pull down when the regulator is disabled.
DESCRIPTION
This struct describes regulator operations which can be implemented by regulator chip drivers.
AUTHORS
Liam Girdwood <lrg [at] slimlogic.co.uk>
- Author.
Mark Brown <broonie [at] opensource.wolfsonmicro.com>
Wolfson Microelectronics,
COPYRIGHT