fence_ldom (8) - Linux Manuals
fence_ldom: Fence agent for Sun LDOM
NAME
fence_ldom - Fence agent for Sun LDOMDESCRIPTION
fence_ldom is an I/O Fencing agent which can be used with LDoms virtual machines. This agent works so, that run ldm command on host machine. So ldm must be directly runnable. Very useful parameter is -c (or cmd_prompt in stdin mode). This must be set to something, what is displayed after successful login to host machine. Default string is space on end of string (default for root in bash). But (for example) csh use ], so in that case you must use parameter -c with argument ]. Very similar situation is, if you use bash and login to host machine with other user than root. Than prompt is $, so again, you must use parameter -c. fence_ldom accepts options on the command line as well as from stdin. Fenced sends parameters through stdin when it execs the agent. fence_ldom can be run by itself with command line options. This is useful for testing and for turning outlets on or off from scripts.Vendor URL: http://www.sun.com
PARAMETERS
- -o, --action=<action>
-
Fencing Action (Default Value: reboot)
- -a, --ip=<ip>
-
IP Address or Hostname This parameter is always required.
- -l, --username=<name>
-
Login Name This parameter is always required.
- -p, --password=<password>
-
Login password or passphrase
- -S, --password-script=<script>
-
Script to retrieve password
- -x, --ssh
-
SSH connection (Default Value: true)
- -k, --identity-file=<filename>
-
Identity file for ssh
- -n, --plug=<id>
-
Physical plug number or name of virtual machine This parameter is always required.
- -c, --command-prompt=<prompt>
-
Force command prompt (Default Value:
$)
- -4, --inet4-only
- Forces agent to use IPv4 addresses only
- -6, --inet6-only
- Forces agent to use IPv6 addresses only
- -u, --ipport=<port>
- TCP port to use for connection with device
- -v, --verbose
- Verbose mode
- -D, --debug-file=<debugfile>
- Write debug information to given file
- -V, --version
- Display version information and exit
- -h, --help
- Display help and exit
- -C, --separator=<char>
- Separator for CSV created by operation list (Default Value: ,)
- --power-timeout
- Test X seconds for status change after ON/OFF (Default Value: 20)
- --shell-timeout
- Wait X seconds for cmd prompt after issuing command (Default Value: 3)
- --login-timeout
- Wait X seconds for cmd prompt after login (Default Value: 5)
- --power-wait
- Wait X seconds after issuing ON/OFF (Default Value: 0)
- --retry-on
- Count of attempts to retry power on (Default Value: 1)
- --delay
- Wait X seconds before fencing is started (Default Value: 0)
ACTIONS
- on
-
Power on machine.
- off
-
Power off machine.
- reboot
-
Reboot machine.
- status
-
This returns the status of the plug/virtual machine.
- list
-
List available plugs with aliases/virtual machines if there is support for more then one device. Returns N/A otherwise.
- monitor
-
Check if fencing device is running. List available plugs/virtual machines or get status of machine (if it does not support more).
- metadata
-
The operational behavior of this is not known.
STDIN PARAMETERS
- action
-
Fencing Action (Default Value: reboot)
- ipaddr
-
IP Address or Hostname This parameter is always required.
- login
-
Login Name This parameter is always required.
- passwd
-
Login password or passphrase
- passwd_script
-
Script to retrieve password
- secure
-
SSH connection (Default Value: true)
- identity_file
-
Identity file for ssh
- port
-
Physical plug number or name of virtual machine This parameter is always required.
- cmd_prompt
-
Force command prompt (Default Value:
$)
- inet4_only
- Forces agent to use IPv4 addresses only
- inet6_only
- Forces agent to use IPv6 addresses only
- ipport
- TCP port to use for connection with device
- verbose
- Verbose mode
- debug
- Write debug information to given file
- version
- Display version information and exit
- help
- Display help and exit
- separator
- Separator for CSV created by operation list (Default Value: ,)
- power_timeout
- Test X seconds for status change after ON/OFF (Default Value: 20)
- shell_timeout
- Wait X seconds for cmd prompt after issuing command (Default Value: 3)
- login_timeout
- Wait X seconds for cmd prompt after login (Default Value: 5)
- power_wait
- Wait X seconds after issuing ON/OFF (Default Value: 0)
- retry_on
- Count of attempts to retry power on (Default Value: 1)
- delay
- Wait X seconds before fencing is started (Default Value: 0)