fence_hpblade (8) - Linux Manuals
fence_hpblade: Fence agent for HP BladeSystem
NAME
fence_hpblade - Fence agent for HP BladeSystemDESCRIPTION
fence_hpblade is an I/O Fencing agent which can be used with HP BladeSystem and HP Integrity Superdome X. It logs into the onboard administrator of an enclosure via telnet or ssh and uses the command line interface to power blades or partitions on or off.
fence_hpblade accepts options on the command line as well as from stdin. Fenced sends parameters through stdin when it execs the agent. fence_hpblade can be run by itself with command line options. This is useful for testing and for turning outlets on or off from scripts.
Vendor URL: http://www.hp.com
PARAMETERS
- -u, --ipport=[port]
-
TCP/UDP port to use for connection with device (Default Value: 23)
- -a, --ip=[ip]
-
IP Address or Hostname This parameter is always required.
- -n, --plug=[id]
-
Physical plug number, name of virtual machine or UUID This parameter is always required.
- -x, --ssh
-
SSH connection
- -c, --command-prompt=[prompt]
-
Force Python regex for command prompt (Default Value: ['c7000oa>'])
- -6, --inet6-only
-
Forces agent to use IPv6 addresses only
- -k, --identity-file=[filename]
-
Identity file for ssh
- -4, --inet4-only
-
Forces agent to use IPv4 addresses only
- -S, --password-script=[script]
-
Script to retrieve password
- -p, --password=[password]
-
Login password or passphrase
- --ssh-options=[options]
-
SSH options to use
- -o, --action=[action]
-
Fencing Action (Default Value: reboot)
- -l, --username=[name]
-
Login Name This parameter is always required.
- -v, --verbose
-
Verbose mode
- -D, --debug-file=[debugfile]
-
Write debug information to given file
- -V, --version
-
Display version information and exit
- -h, --help
-
Display help and exit
- -C, --separator=[char]
-
Separator for CSV created by operation list (Default Value: ,)
- --power-wait=[seconds]
-
Wait X seconds after issuing ON/OFF (Default Value: 0)
- --login-timeout=[seconds]
-
Wait X seconds for cmd prompt after login (Default Value: 10)
- --power-timeout=[seconds]
-
Test X seconds for status change after ON/OFF (Default Value: 20)
- --delay=[seconds]
-
Wait X seconds before fencing is started (Default Value: 0)
- --shell-timeout=[seconds]
-
Wait X seconds for cmd prompt after issuing command (Default Value: 3)
- --missing-as-off
-
Missing port returns OFF instead of failure
- --retry-on=[attempts]
-
Count of attempts to retry power on (Default Value: 1)
ACTIONS
- on
-
Power on machine.
- off
-
Power off machine.
- reboot
-
Reboot machine.
- status
-
This returns the status of the plug/virtual machine.
- list
-
List available plugs with aliases/virtual machines if there is support for more then one device. Returns N/A otherwise.
- list-status
-
List available plugs with aliases/virtual machines and their power state if it can be obtained without additional commands.
- monitor
-
Check the health of fence device
- metadata
-
Display the XML metadata describing this resource.
STDIN PARAMETERS
- ipport
-
TCP/UDP port to use for connection with device (Default Value: 23)
- ipaddr
-
IP Address or Hostname This parameter is always required.
- port
-
Physical plug number, name of virtual machine or UUID This parameter is always required.
- secure
-
SSH connection
- cmd_prompt
-
Force Python regex for command prompt (Default Value: ['c7000oa>'])
- inet6_only
-
Forces agent to use IPv6 addresses only
- identity_file
-
Identity file for ssh
- inet4_only
-
Forces agent to use IPv4 addresses only
- passwd_script
-
Script to retrieve password
- passwd
-
Login password or passphrase
- ssh_options
-
SSH options to use
- action
-
Fencing Action (Default Value: reboot)
- login
-
Login Name This parameter is always required.
- verbose
-
Verbose mode
- debug
-
Write debug information to given file
- version
-
Display version information and exit
- help
-
Display help and exit
- separator
-
Separator for CSV created by operation list (Default Value: ,)
- power_wait
-
Wait X seconds after issuing ON/OFF (Default Value: 0)
- login_timeout
-
Wait X seconds for cmd prompt after login (Default Value: 10)
- power_timeout
-
Test X seconds for status change after ON/OFF (Default Value: 20)
- delay
-
Wait X seconds before fencing is started (Default Value: 0)
- shell_timeout
-
Wait X seconds for cmd prompt after issuing command (Default Value: 3)
- missing_as_off
-
Missing port returns OFF instead of failure
- retry_on
-
Count of attempts to retry power on (Default Value: 1)