sd_journal_set_data_threshold (3) - Linux Manuals
sd_journal_set_data_threshold: Read data fields from the current journal entry
NAME
sd_journal_get_data, sd_journal_enumerate_data, sd_journal_restart_data, SD_JOURNAL_FOREACH_DATA, sd_journal_set_data_threshold, sd_journal_get_data_threshold - Read data fields from the current journal entry
SYNOPSIS
#include <systemd/sd-journal.h>
-
int sd_journal_get_data(sd_journal
* j, const char* field, const void** data, size_t* length);- int sd_journal_enumerate_data(sd_journal
* j, const void** data, size_t* length);- void sd_journal_restart_data(sd_journal
* j);- SD_JOURNAL_FOREACH_DATA(sd_journal
* j, const void* data, size_tlength); - int sd_journal_set_data_threshold(sd_journal
* j, size_tsz); - int sd_journal_get_data_threshold(sd_journal
* j, size_t* sz); - int sd_journal_enumerate_data(sd_journal
DESCRIPTION
sd_journal_get_data()
sd_journal_enumerate_data() may be used to iterate through all fields of the current entry. On each invocation the data for the next field is returned. The order of these fields is not defined. The data returned is in the same format as with sd_journal_get_data() and also follows the same life-time semantics.
sd_journal_restart_data() resets the data enumeration index to the beginning of the entry. The next invocation of sd_journal_enumerate_data() will return the first field of the entry again.
Note that the SD_JOURNAL_FOREACH_DATA() macro may be used as a handy wrapper around sd_journal_restart_data() and sd_journal_enumerate_data().
Note that these functions will not work before sd_journal_next(3) (or related call) has been called at least once, in order to position the read pointer at a valid entry.
sd_journal_set_data_threshold() may be used to change the data field size threshold for data returned by sd_journal_get_data(), sd_journal_enumerate_data() and sd_journal_enumerate_unique(). This threshold is a hint only: it indicates that the client program is interested only in the initial parts of the data fields, up to the threshold in size -- but the library might still return larger data objects. That means applications should not rely exclusively on this setting to limit the size of the data fields returned, but need to apply a explicit size limit on the returned data as well. This threshold defaults to 64K by default. To retrieve the complete data fields this threshold should be turned off by setting it to 0, so that the library always returns the complete data objects. It is recommended to set this threshold as low as possible since this relieves the library from having to decompress large compressed data objects in full.
sd_journal_get_data_threshold() returns the currently configured data field size threshold.
RETURN VALUE
sd_journal_get_data() returns 0 on success or a negative errno-style error code. If the current entry does not include the specified field, -ENOENT is returned. If sd_journal_next(3) has not been called at least once, -EADDRNOTAVAIL is returned. sd_journal_enumerate_data() returns a positive integer if the next field has been read, 0 when no more fields are known, or a negative errno-style error code. sd_journal_restart_data() returns nothing. sd_journal_set_data_threshold() and sd_journal_get_threshold() return 0 on success or a negative errno-style error code.
NOTES
The
sd_journal_get_data(),
sd_journal_enumerate_data(),
sd_journal_restart_data(),
sd_journal_set_data_threshold()
and
sd_journal_get_data_threshold()
interfaces are available as a shared library, which can be compiled and linked to with the
libsystemd
See
sd_journal_next(3)
for a complete example how to use
sd_journal_get_data().
Use the
SD_JOURNAL_FOREACH_DATA
macro to iterate through all fields of the current journal entry:
systemd(1),
systemd.journal-fields(7),
sd-journal(3),
sd_journal_open(3),
sd_journal_next(3),
sd_journal_get_realtime_usec(3),
sd_journal_query_unique(3)
EXAMPLES
...
int print_fields(sd_journal *j) {
const void *data;
size_t length;
SD_JOURNAL_FOREACH_DATA(j, data, length)
printf("%.*s\n", (int) length, data);
}
...