NAME
euwatch-put-metric-alarm - Create or update an alarm
SYNOPSIS
euwatch-put-metric-alarm
--comparison-operator
- {GreaterThanOrEqualToThreshold,GreaterThanThreshold,LessThanThreshold,LessThanOrEqualToThreshold}
-
--evaluation-periods COUNT --metric-name
METRIC --namespace NAMESPACE --period SECONDS
--statistic
{Average,Maximum,Minimum,SampleCount,Sum}
--threshold FLOAT
[--actions-enabled {true,false}]
[--alarm-actions ARN1,ARN2,...]
[--alarm-description DESCRIPTION]
[-d KEY1=VALUE1,KEY2=VALUE2,...]
[--insufficient-data-actions ARN1,ARN2,...]
[--ok-actions ARN1,ARN2,...] [--unit UNIT]
[--show-empty-fields] [-U URL]
[--region USER [at] REGION] [-I KEY_ID] [-S KEY]
[--security-token TOKEN] [--debug]
[--debugger] [--version] [-h]
ALARM
DESCRIPTION
Create or update an alarm
positional arguments:
- ALARM
-
name of the alarm (required)
optional arguments:
- --comparison-operator {GreaterThanOrEqualToThreshold,GreaterThanThreshold,LessThanThreshold,LessThanOrEqualToThreshold}
-
arithmetic operator with which the comparison with the
threshold will be made (required)
- --evaluation-periods COUNT
-
number of consecutive periods for which the value of
the metric needs to be compared to the threshold
(required)
- --metric-name METRIC
-
name for the alarm's associated metric (required)
- --namespace NAMESPACE
-
namespace for the alarm's associated metric (required)
- --period SECONDS
-
period over which the specified statistic is applied
(required)
- --statistic {Average,Maximum,Minimum,SampleCount,Sum}
-
statistic on which to alarm (required)
- --threshold FLOAT
-
value to compare the statistic against (required)
- --actions-enabled {true,false}
-
whether this alarm's actions should be executed when
it changes state
- --alarm-actions ARN1,ARN2,...
-
ARNs of SNS topics to publish to when the alarm
changes to the ALARM state
- --alarm-description DESCRIPTION
-
description of the alarm
- -d KEY1=VALUE1,KEY2=VALUE2,..., --dimensions KEY1=VALUE1,KEY2=VALUE2,...
-
dimensions for the alarm's associated metric
- --insufficient-data-actions ARN1,ARN2,...
-
ARNs of SNS topics to publish to when the alarm
changes to the INSUFFICIENT_DATA state
- --ok-actions ARN1,ARN2,...
-
ARNs of SNS topics to publish to when the alarm
changes to the OK state
- --unit UNIT
-
unit for the alarm's associated metric
- --show-empty-fields
-
show empty values as "(nil)"
- -U URL, --url URL
-
instance monitoring service endpoint URL
- --region USER [at] REGION
-
region and/or user names to search when looking up
config file data
-
-I KEY_ID, --access-key-id KEY_ID
-
-S KEY, --secret-key KEY
-
--security-token TOKEN
- --debug
-
- show debugging output
- --debugger
-
launch interactive debugger on error
- --version
-
show the program's version and exit
- -h, --help
-
show this help message and exit